LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (Refrigerant R1234YF Servicing) (2 Of 2) >> 87 Air Conditioning >> Refrigerant Circuit >> Leaks, Finding >> Leaks, Finding With UV Leak Detection System >> Add the UV-Leak Detection Additive to the Refrigerant Circuit Using the A/C Service Station.

Add the UV-Leak Detection Additive to the Refrigerant Circuit Using the A/C Service Station.

-- Fill the UV-leak detection additive and the specified refrigerant quantity in the refrigerant circuit using the A/C service station. Refer to REFRIGERANT CIRCUIT, CHARGING  and Technical Data .

NOTE:

The quantity of UV-leak detection additive which is filled on a refrigerant circuit with a refrigerant oil quantity up to 150 cm3 is 3.0 + /- 0.5 ml (cm3 ). If the refrigerant oil capacity in the refrigerant circuit is larger, then more UV leak detection additive must be added accordingly (for example, 5.0 ± 0.5 (cm3 ) for a refrigerant circuit with a refrigerant oil capacity of 250 cm 3 . When filling the UV-leak detection additive using an A/C service station the set quantity in the A/C service station can vary for this reason pay attention to the corresponding Owner's Manual. Refer to A/C service station Owner's Manual.

The actual refrigerant oil quantity in the refrigerant circuit can be found in the vehicle-specific Service Information. Refer to Technical Data .

If UV-leak detection additive was filled already in a refrigerant circuit for an earlier repair, note the following: only add new UV-leak detection additive if the refrigerant oil will be replaced. If only a portion of the refrigerant oil was replaced, only add a proportionate amount of the UV-leak detection additive. For example, if 50 ml of refrigerant oil was replaced in a vehicle with 150 ml, add only 1.0 ml (cm3 ) of UV-leak detection additive.

The leak detection system has the following components:

Fig 1: Identifying Leak Detection System VAS 6201
GWWA87-0494Courtesy of AUDI OF AMERICA, LLC
NOTE:

Ignore items -1, 2 and 7- in the image.

-- Evacuate the refrigerant circuit according to the procedure and fill with UV-leak detection additive and refrigerant. Refer to REFRIGERANT CIRCUIT, EVACUATING  and REFRIGERANT CIRCUIT, CHARGING .

-- Wait until the pressure in the high and low pressure side have equalized.

-- Disconnect and the A/C service station from the refrigerant circuit and turn it off. Refer to A/C SERVICE STATION, SWITCHING OFF AND DISCONNECTING FROM REFRIGERANT CIRCUIT .

-- Apply a label near the service connections stating that UV-leak detection additive was added to the refrigerant circuit.

Fig 2: Identifying Leak Detection Additive Label
GWWA87-0495Courtesy of AUDI OF AMERICA, LLC

-- Remove the residual UV-leak detection additive for example with absorbent paper from the service connection and the surrounding area and clean using Leak Detection Kit - Cleaning Solution :VAS6201/3  .

-- Seal the service connection using closure caps.

-- Start the A/C system.

-- Operate the A/C system for at least 60 minutes with the A/C compressor switched on.

-- Check for leaks on the refrigerant circuit using UV lamp. Refer to Check for Leaks on the Refrigerant Circuit Using UV Lamp. .