Install the electric changeover valve for the vacuum control of the coolant pump
NOTE:
TECHNICAL INFORMATION
Detents, guides and mounting elements must not be damaged or missing.
Detents, guides and mounting elements must not be damaged or missing.
- Connect the electric changeover valve (4) to the holder.
- Make sure that the green O-ring between the red vacuum hose (2) and the electric changeover valve (4) is installed correctly.
The vacuum hose (2) is red.
The vacuum hose (3) is black.
- Connect plug (1).
- Connect the vacuum hoses (2) and (3) to the electric changeover valve (4).
Follow-up work
- Refer to INSTALLING THE INTAKE PLENUM .
- Refer to INSTALLING CONTROL UNIT BRACKET .
- Refer to INSTALLING THE DME CONTROL UNIT .
- Refer to INSTALLING THE TANK VENT VALVE .
- Refer to INSTALLING ACOUSTIC COVER AT REAR .
- Refer to INSTALLING THE FRONT HOOD SEAL AT THE REAR .
- Refer to INSTALLING THE ACOUSTIC COVER FOR THE ENGINE AT THE FRONT .
- Refer to INSTALLING CHARGE AIR LINE .
- Refer to CONNECTING THE COOLANT LINE OF LOW-TEMPERATURE COOLANT CIRCUIT .
- Refer to FILLING THE LOW-TEMPERATURE COOLING SYSTEM WITH THE VACUUM FILLING EQUIPMENT .
- Refer to INSTALLING CLEAN AIR PIPE .
- Refer to INSTALLING RESONATOR .
- Refer to INSTALLING ACOUSTIC COVER .
- Refer to VENTING THE LOW-TEMPERATURE COOLING SYSTEM .
- Refer to INSTALLING THE UNDERBODY PROTECTION OF THE STEERING GEAR OR THE FRONT THRUST FIELD .
- Refer to INSTALLING THE FRONT UNDERBODY PROTECTION OR FRONT THRUST FIELD .
